9704 Gen 4 R3D® Module
Remote-Read Level Sensors for use with Rochester R3D Dial
Maximize your fluid level detection capabilities with Rochester Sensors remote-read R3D modules. Incorporating a remote-read system allows you to monitor your fluid or fuel levels remotely, providing a reliable, safe, and convenient solution to track usage. The ratiometric voltage output from Rochester 9704 remote-read modules allows you to accurately measure tank levels and integrates easily into any automated monitoring system.
Application
The Rochester 9704 module snap-fits into the recess of your existing Rochester Sensors R3D remote-ready dial lens to provide a low power, cost-effective solution to transmit fluid levels. The sensors detect the position of the fluid level indicator in the dial it is attached to. Using the module’s onboard microprocessor, this positional data is converted to a ratiometric voltage output (0V to VCC) dependent on the supply voltage. This output voltage can be utilized by the end user’s wired, or wireless monitoring device to transmit the fluid level inside a tank. Corresponding voltage-out to percentage-full tables are available for all Rochester R3D dials. 9704 Modules require a 3-5VDC input and have a very low current draw that is excellent for battery powered applications.
General Information & Features
- Cable length up to 25ft max (6 ft. standard length) with flying leads
- 22AWG – 3 Conductor Cable for power (VCC), ground, and signal (Vout)
- Accuracy: Module output +/- 2% of visual dial indication. (Float gauge errors not included).
- Repeatability: +/- 1%
- Operational Voltage Range: 2.6 to 5.5 VDC
- Output Voltage: Ratiometric, percent of supply voltage
- Resolution: 0.018V
- Operating Current: 4mA Typical @ 5 VDC with 1M load on output
- Recommended Load Impedance: > 10k, 0.5nF for optimal performance
- Turn-on time: 5 mS Typical
Operating Temperature Range:
- Dynamic -25°C to +80°C; Static -30°C to + 80°C
- Storage Temperature: -40°C to +105°C
- Ingress Protection: IP69K rated
- Intrinsically safe in explosive atmospheres
Product Construction
The 9704 product is centered around a position-sensing integrated circuit that works with existing R3D level dials. The sensor is available in both a 45-degree, side exit, and straight orientation. The custom printed circuit board, components, and all electrical connections are fully enclosed in a durable molded polyamide casing which provides excellent insulation and environmental protection. Alignment and snap-fit geometry are
integrated into the shape of the sensor to perfectly mate with the remote-read slots on all Rochester Sensors R3D dial faces. Interaction with the 9704 module is accomplished via a multi conductor jacketed cable. The
black 600V, 105°C cable is UL Recognized (21768) with a TPU jacket that is oil, water, UV, and cold resistant. The three internal 22 AWG stranded wires are colored for easy assembly into the end user’s monitoring device.
Product Function Overview
The 9704 module can be inserted into to any R3D dial face to detect the fluid level indicated. The sensor accomplishes this by detecting the direction that the level indicator is pointing on the dial. The 9704 module then converts this raw positional data to a percentage of the supply voltage. As fluid levels decrease, the voltage on the signal line will also decrease, proportional to the supply voltage. (Example: At 50% full tank level = the signal voltage will read approximately half of the supply voltage level.) See dial tables for more specific voltage-to-percentage conversions. The 9704 modules use a 3-wire cable to connect to the user’s
monitoring system: supply voltage (3-5V), ground, and ratiometric Vout signal.
Documents
9704 Data Sheet
9704 Installation Guide
0115-0113
0115-01194
0115-0119
WD-580
Reference the following documents for nominal output voltages corresponding with dial graduations: DS-1828: ASME Horizontal Tanks, Vertical Tanks/DOT Cylinders, and Industrial Tanks (Fractional)
Reference DS-2010A for module installation instructions
Remote-Read Level Sensors for use with Rochester R3D® Dials
Ordering Information
Part Number: 9704-ABCXXXM (Example: 9704-FD106M)
9704 = Product Family
A – Specify orientation of module: (F = 45°, S = Straight, T = Side Exit)
B – Specify Rochester Sensors dial type (D = Domestic Jr. & Sr. Dials,
M = Magnetel Dials)
C – Cable type (C=1 for standard Rochester cable)
XX – Specify cable length 00ft. – 25ft. (Standard length is 6ft. = 06)
M = Molded construction
Warning: For LP-Gas and other flammable product service applications, connect only to circuits and power sources classified and labeled Intrinsically Safe for Class 1, Division 1, Group C and D hazardous locations. Connection of non-intrinsically safe power could result in fire or explosion of flammable vapor which may be present.
Warning: Sensor not to be used as the primary means of determining high or low fuel condition. It must not be used in the absence of redundant systems in critical applications where there may be significant safety risk or financial exposure in the event of fuel overfill or fuel exhaustion condition. This sensor is not to be used for tank filling.
Warning: Level Gauging devices and sensors sold by Rochester Sensors. are components only.
The purchaser/installer is solely responsible for the application of these components and ensuring all necessary steps have been taken to assure each application and use meets all performance and applicable safety requirements, and/or local, national and/or international safety codes as required by the application. Rochester Sensors. cannot certify that our products used solely or in conjunction with other Rochester Sensors. or other vendors’ products will assure desired performance and safety for any application.
Any person using or applying any products sold by Rochester Sensors. is responsible for learning the performance and safety requirements for their individual application and applying them, and therefore assumes, all risks, and accepts full and complete responsibility of the product for their respective application. Rochester Sensors. does not provide system design or consulting services, and cannot advise whether any specific application or use of our products would ensure compliance with all performance and safety requirements for any application.