Consent Preferences
WarningFlammable

Serie 6400

Toda la construcción de acero inoxidable para aplicaciones altamente corrosivas

Application
The 6400 Series Senior Gauges are especially designed for chemical service with all wetted parts made of stainless steel except the nickel-plated Alnico drive magnet.

General Information & Features
The 6400 Series gauges are available in gear-action models for top, centerline or angle mounting, or in lever-action models for centerline mounting only. They are mounted to tank using Senior flanges 2 1⁄2″ bolt circle [63,5] by four #0040-00666 5⁄16 -24 x 3⁄4 bolts. A #0015-00462 spiral-wound, Teflon gasket is standard.

Documents
Data Sheet
MS-501/502 Installation Instructions
Adapters 22 Series – Senior Stainless Steel

Número de modelo Acción Montaje Datos del dial, del remitente o del interruptor
6440 Engranaje Arriba Mayor TwinSite ® Sender en la elección de 0-30, 0-90, o 240-30 ohmios rangos. También se pueden utilizar diales de lectura directa.
6443 C/L o ángulo
L6443 Palanca C/L
6450 Engranaje Arriba Standard switch #5023s00778 S.P.S.T. VAC/50 VDC 1/2 Amp. Please furnish tank drawings and switch points so proper gauge and calibration can be supplied. Other switches available, see DS-364.
6453 C/L o ángulo
L6453 Palanca C/L
6460 Engranaje Arriba #5002s00570 la lectura secundaria superior fraccional.
6480 #5002s00062 fraccional superior de lectura directa.
6483 C/L o ángulo
L6483 Palanca C/L #5002s00547 fraccional superior de lectura directa.
6490 Engranaje Arriba #5013s00456 4 dial fraccional de ″.
6493 C/L o ángulo
L6493 Nivel C/L

Gallonage and percentage dials are available for models 6480 through L6493 at extra cost.



Especificaciones generales *

Accuracy
Accuracy depends upon proper gauge sizing. Senior dials +/-6%, TwinSite® dials +/-10%. Accuracy may be less depending upon tank shape. Accuracy may be less near full and empty. Accuracy may be less if tank is not level. This gauge is not to be used for filling. All accuracy estimates are expressed as a percent of full scale.

Recommended Mounting-Screw Torque
12 lb.-ft. [16,4 Mn]

Temperature
Standard operating temperature range is -40°F to 158°F, -40°C to 70°C. +350°F, 177°C available on special order.

Shock
Passes MIL-S-901 B Naval Standard Shock Test.

Vibration
Passes MIL-STD-167 Naval Standard Vibration Test.

Power
0.5 watts maximum for TwinSite® versions.

Maximum Service Pressure
500PSIG [34 Bar] (Standard). Service pressure up to 575 PSIG [39,6 Bar] available on special order.

Approvals
These direct indicating gauges are UL listed for flammable liquids.

Note: For installation instructions see MS-501/502 (mounting standard).

Materiales de construcción *

Head, Centershaft, Support Tube, Gears, Cross Stud, Gear Housing, Bearings, Float, & Float Rod
Stainless steel.

Drive Magnet
Plated Alnico.

Mounting Bolts
Stainless steel.

Mounting Gasket
Teflon and stainless steel.

Direct-Reading Dial
Aluminum with acrylic crystal, hermetically sealed.

Side-Reading Dial
Aluminum with polycarbonate crystal, hermetically sealed.

Standard 4″ Dial
Aluminum with glass crystal, hermetically sealed.

TwinSite® Sender
Polyamide.

Al ordenar especifique:

1. Gauge model number.
2. Tank diameter and riser height.
3. Mounting locations.
4. OHM range on TwinSite® versions.
5. Preferred switch on switch gauges, if other than standard.
6. Service pressure.
7. Any listed options.

* Los materiales y especificaciones están sujetos a cambios sin previo aviso. Las clasificaciones de presión están sujetas a cambios debido a la temperatura y otras consideraciones medioambientales.

Investigación de producto-6400

    Productos relacionados

    Revisado 04-28-2015